l
a t e s t p r e s s r e l e a
s e s |
|
|
July 15, 2002
|
| |
New EZPhone is Easy on Power
|
|
|
June 24, 2002
|
| |
XE8000 ProStart II, A Smart Development Tool for XE8000 Microcontroller Based Products
|
|
|
June 11, 2002
|
| |
Listen In With EasyBlue
|
|
|
May 27, 2002
|
| |
Biocontrol and XEMICS Announce the First Human Implantation of the MiniatURO
|
|
|
May 6, 2002
|
| |
RFast; XEMICS' Fast RF Evaluation and Development Environment
|
|
|
May 1, 2002
|
| |
Growing demand fuels XEMICS Asia-Pacific expansion
|
|
|
February 11, 2002
|
| |
XEMICS Unleashes its 900MHz Ultra Low-Power Transceiver !
|
|
|
January 28, 2002
|
| |
The most cost effective wireless headset yet
|
|
|
January 15, 2002
|
| |
Dedicated Ultra-Low Power Microcontroller for RF Communication
|
|
|
December 17, 2001
|
| |
XEMICS And PHYTON join forces to create an In-Circuit-Emulator
|
|
|
| |
Biocontrol and XEMICS Announce the First Human Implantation of the MiniatURO |
 |
| |
|
| Neuchâtel,
Switzerland and Mountain View, CA May 27, 2002
|
|
| |
|
BioControl MiniatURO™ is a microelectronic muscle and nerve stimulator,
the size of a small pacemaker that is implanted subcutaneously in an outpatient
procedure for the treatment of mixed urinary incontinence. For individuals
suffering stress incontinence, whenever the MiniatURO™ senses an increase in
abdominal pressure, it applies mild electrical pulses to the pelvic floor
muscles. The pulse activates those muscles preventing undesired urine loss. In
the urge incontinence mode of operation, the MiniatURO™ applies mild electrical
pulses to the pelvic diaphragm nerve, employing the sphincter detrusor reflex to
inhibit bladder contractions. In the mixed case, the two modes of operations are
combined.
The MiniatURO™ primary advantages include: (i) the device is implanted subcutaneously in a minimally invasive fashion, (ii) the implant is performed under local anesthesia in a procedure lasting approximately 30 minutes, (iii) the procedure does not change the natural anatomy and is, if needed, reversible, (iv) the mode of operation mimics the natural physiology, namely the muscle is activated upon demand, and finally (v) the device strengthens the pelvic floor muscle.
This product takes advantage of the XEMICS’ ZoomingADC™, which is integrated into the XE88LC01 Sensing Machine. The ZoomingADC™ can apply a gain of 1000 to the sensing element’s signal, then convert the resulting signal with a resolution of 16 bits. The XE88LC01 can be directly connected to any type of bridge sensor, and benefits from simplified calibration. ''By taking advantage of the level of integration of the XE88LC01 system costs are significantly reduced. However, the ultra-low-power feature of the XE88LC01 was one of main reasons for its suitability in this product,'' said Michel Chevroulet, Product Line Manager at XEMICS.
ABOUT BioControl
BioControl Medical, Ltd., an Israeli company founded in late 1999, is developing second-generation active implantable devices targeted at large market opportunities where there are significant unmet therapeutic needs. BioControl aims to become a world leader providing lifelong solutions to patients with chronic diseases employing active implantable devices that activate and control human muscles and nerves via closed loop feedback mechanisms.
For more details on BioControl please contact:
Dr. Ehud Cohen
COO
BioControl Medical Ltd.
Phone: +972-3-6322126
Fax: +972-3-6322125
E-Mail: udi@biocontrol.co.il
|
|
|